- 1 - Carbon Monoxide Alarm Owner’s Manual Sealed Lithium Battery Powered CA6100 Sealed Lithium Battery Powered CO Alarm, Single Station
- 10 - 8. FUNCTIONS AND OPERATION OPERATION: The CO alarm is operational once the activation switch is slid to ON position. The green LED will fl
- 11 - DISPLAY CO LEVEL BUTTON (FOR MODEL CA6150): To manually display the current and highest CO level detected, press the DISPLAY CO LEV
- 12 - SERVICE red LED glows for 5 seconds at the same time, and model CA6150 continuously displays “End”. To test the alarm during an “
- 13 - Conditions which can result in transient CO situations: 1) Excessive spillage or reverse venting of fuel burning appliances caused by outdoor a
- 14 - 12. GOOD SAFETY HABITS DEVELOP AND PRACTICE A PLAN OF ESCAPE: Make a floor plan indicating all doors and windows and at least two escape rout
- 15 - To remove the alarm for service or disposal, unscrew the mounting screw from the top center of the alarm, and slide the alarm up and off the
- 16 - 14. DESCRIPTION OF AUDIBLE AND VISUAL SIGNALS Condition LCD Readout LEDs Horn CO alarm is operational Displays continuously Green LED fl
- 17 - 15. TEN-YEAR LIMITED WARRANTY The Defender carbon monoxide alarms are manufactured in Canada under stringent ISO 9001 quality management prac
- 2 - CONTENTS OF THIS MANUAL 1. IMPORTANT MESSAGE AND INSTRUCTIONS 2. WARNING MESSAGES 3. FEATURES AND SPECIFICATIONS 4. INFORMATION ABOUT CAR
- 3 - the other label near a source of fresh air where you plan to gather when the carbon monoxide alarm signals are activated. After installation i
- 4 - 3. FEATURES AND SPECIFICATIONS Factory Sealed Lithium Batteries with Soldered Connections Integrated Battery Activation/Deactivation Swit
- 5 - SPECIFICATIONS CO Response Times: 70 PPM: 60-240 minutes, 150 PPM: 10-50 minutes, 400 PPM: 4-15 minutes, Sensor Type: Electrochemic
- 6 - 4. INFORMATION ABOUT CARBON MONOXIDE WHAT IS CARBON MONOXIDE? Carbon monoxide (CO) is a highly toxic, invisible, odorless, tasteless gas. HO
- 7 - 5. RECOMMENDED LOCATION OF ALARMS The Consumer Products Safety Commission (CPSC) recommends the use of "at least one CO alarm per househol
- 8 - 6. LOCATIONS TO AVOID NEAR THE COOKING AREA: Do not install the alarm within five feet of cooking appliances. CO may be generated i
- 9 - Mounting hole is closed when switch is in initial positionTo activate CO Alarm, slide thealarm down onto mounting plate, orslide to